Peptide COA guide
How to read a Certificate of Analysis.
A Certificate of Analysis (COA) is the laboratory record for one batch of material. Here's what each section means and how to match a report to the vial in front of you.
The basics
What is a peptide COA?
A peptide COA (Certificate of Analysis) is the lab report for one specific lot of a research peptide. It shows what the material is (identity by mass spectrometry), how clean it is (purity by HPLC) and, often, how much is in each vial.
A COA describes analytical results only. It does not show that a material is safe for people or animals. PURE materials are sold for lawful in-vitro research use only.
Already have a vial? Enter its lot number on Verify a Batch to open the matching peptide COA.
What's on a COA
Six things to check on a peptide COA
01
Product name and lot number
The lot (batch) number on the report must match the lot printed on your vial label. A COA only describes the batch it names — a report for a different lot tells you nothing about your vial.
02
Purity (HPLC)
High-performance liquid chromatography separates a sample into its components. Purity is reported as the main peak's share of the total, for example 99.1%. Look for the chromatogram itself, not just a number.
03
Identity (mass spectrometry)
Mass spectrometry provides evidence of identity by comparing measured signals with the expected mass and charge states. Review the laboratory's method and interpretation; a matching mass alone does not establish sequence or rule out every impurity. Purity without identity evidence is incomplete.
04
Quantity or content
Some reports state the measured amount per vial (for example 10 mg). Look for a quantitative content assay and its method, separately from purity; a label claim or HPLC peak-area percentage is not a measurement of milligrams per vial.
05
Test date and laboratory
Every report should show when the sample was tested and which laboratory performed the analysis, so the document can be traced.
06
Supplier and report ID
Reports carry their own reference number. One product can have several reports over time as new lots arrive, sometimes from different suppliers.
Annotated example
A sample peptide COA, explained
Illustrative example only. The values below are made up to show where each item appears; they are not a report for any PURE lot.
CERTIFICATE OF ANALYSIS
- ①
- Product: Example Peptide · Lot: EX-2410-07
- ②
- HPLC purity: 99.2% (main peak area, 220 nm)
- ③
- MS identity: observed 1419.6 Da · theoretical 1419.5 Da · Conforms
- ④
- Measured content: 10.3 mg per vial (label 10 mg)
- ⑤
- Test date: 2026-10-14 · Laboratory: Independent Analytical Lab
- ⑥
- Report ID: IAL-58213
Chromatogram: one tall main peak, small impurity bumps.
- ① Lot — match this to the lot printed on your vial.
- ② Purity — how much of the sample is the target compound, shown with its chromatogram.
- ③ Identity — compare the observed signal with the expected mass and charge state using the lab's method-specific tolerance, not a universal 1 Da rule.
- ④ Content — how much material is in the vial, a separate measure from purity.
- ⑤ Date and lab — makes the result traceable to a real test.
- ⑥ Report ID — lets you look up the exact document on Verify a Batch.
Red flags
When to ask questions
- The lot number on the report doesn't match your vial.
- A purity figure with no chromatogram or laboratory name.
- No identity test (mass spectrometry) at all.
- No test date, or one report reused for every batch.
If anything looks wrong, contact us before using the material in your research.
Frequently asked questions
How do I verify a research supplier like PURE?
Start with the exact product, size and lot you intend to purchase. Ask for its original laboratory report, check the report ID, test date and methods, and verify any uncertainties with the issuing laboratory using independently located contact details. Review the supplier's contact information, terms, shipping and returns policies, and research-use restrictions. Apply the same checks to PURE; branding, reviews and a high purity percentage are not substitutes for evidence.
What is the difference between a COA and an original lab report?
A Certificate of Analysis may be a supplier's summary of test results or the laboratory's own certificate. The original laboratory report is the issuing lab's record of the sample, methods and findings. Ask which document you are viewing and request supporting chromatograms, identity data and content measurements where available. Neither document alone establishes the entire chain of custody.
How can I check whether a lab report is genuine?
Check the laboratory name, report ID, sample description, lot and dates. If the lab offers report verification, use its official website or contact it through details found independently of the supplier's PDF. Ask whether the report is authentic and unaltered, and what sample it covers; the lab may need its client's permission to disclose details. A logo, QR code or screenshot alone is not proof of authenticity.
Does 99% purity prove the vial contains the stated milligrams or is sterile?
No. HPLC purity is usually a peak-area percentage under a particular method, not the quantity per vial or proof of sterility. Content, sterility, endotoxins, residual solvents and other contaminants require their own appropriate tests. If a result is not documented, treat it as unknown rather than assuming it passed.
What should I check if a laboratory claims accreditation?
Verify the current certificate and scope through the named accreditation body's directory. ISO/IEC 17025 accreditation applies to the activities listed in that scope, not automatically to every test or product. Independent testing and accreditation are different claims; do not assume either without supporting documentation.
What does PURE's Research Use Only policy mean?
PURE supplies materials exclusively for lawful nonclinical, in-vitro laboratory research to eligible researchers aged 21 or older. Products are not for human or animal administration, consumption, injection, clinical, diagnostic or therapeutic use. PURE does not provide dosing or administration instructions. RUO labeling is not FDA approval, a legal exemption, or permission for personal experimentation; researchers remain responsible for applicable laws and institutional requirements.
What if a report is missing or does not match my lot?
Pause use in your research and contact PURE with the product, size, printed lot and report ID if available. Keep the vial, packaging and documentation for review. Do not substitute a report from another batch or treat an AI summary as the original evidence. Review the published Terms & Conditions and Returns, Refunds & Order Cancellation Policy for applicable reporting requirements.
Does a COA mean a product is safe for people?
No. A COA documents the analytical results for a lot. PURE materials are sold for lawful in-vitro research use only and are not for human or animal use.
Why does one product show more than one report?
Each lot is tested separately. PURE keeps every report for a product so you can review the exact batch you received.
What is a peptide COA?
A peptide COA is the laboratory report for one lot of a research peptide. It records purity (HPLC), identity (mass spectrometry), often the measured content per vial, the test date and the laboratory that ran the analysis.
Is every peptide COA lot-specific?
It should be. A trustworthy peptide COA names the exact lot it tested. At PURE, every report is stored against its lot so you can look up the one that matches your vial.
Where do I find the report for my vial?
Enter the lot number from your vial on the Verify a Batch page, or open the lab report section on the product page.
For accreditation checks, consult the A2LA accredited laboratory directory or the directory of the accreditation body named by the lab. This is a verification resource, not a claim that PURE or any particular report is accredited.